亚洲中文有码字幕日本第一页,亚洲国产精品悠悠久久琪琪,亚洲午夜精品久久久久久人妖,亚洲精品中文字幕乱码,亚洲国产精品久久久久婷婷软件

產(chǎn)品展廳收藏該商鋪

您好 登錄 注冊(cè)

當(dāng)前位置:
深圳市長(zhǎng)利來(lái)科技有限公司>>手提式PH儀>>便攜式pH計(jì)>>PH-907手提式PH計(jì)(PH-907)

手提式PH計(jì)(PH-907)

返回列表頁(yè)
  • 手提式PH計(jì)(PH-907)

收藏
舉報(bào)
參考價(jià) 面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 型號(hào) PH-907
  • 品牌
  • 廠商性質(zhì) 生產(chǎn)商
  • 所在地 深圳市

在線詢價(jià) 收藏產(chǎn)品

更新時(shí)間:2017-07-21 18:29:13瀏覽次數(shù):225

聯(lián)系我們時(shí)請(qǐng)說(shuō)明是化工機(jī)械設(shè)備網(wǎng)上看到的信息,謝謝!

化工機(jī)械設(shè)備網(wǎng)采購(gòu)部電話:0571-88918531QQ:2568841715

聯(lián)系方式:查看聯(lián)系方式

產(chǎn)品簡(jiǎn)介

手提式PH計(jì)(PH-907)
PH-907 portable PH INSTRUCTION
BASIC CON:suitcase,9V battery ,combination PH sensor,buffer 7.00and4.00, manual。

詳細(xì)介紹

 

PH-907  portable PH  INSTRUCTION

BASIC CONsuitcase,9V battery ,combination PH sensor,buffer 7.00and4.00 manual。

 

一、           Panel instruction

l        ON/OFF : power switch

l        MODE : function switch,

Repeating:PH →MV→ TEMP  every press

l        CALIB  : 7.00 calibration (6.86)

l        SLOP   : 4.00 calibration (9.18、10.01)

l        TEMP   :  temp compensation manually

 

 

二、           Easy to operate

1、Put the sensor in water , Turn the power on ,and LCD display current PH value ,if you need to calibrate , please check the calibration part of the manual. Wait for the reading to stabilize. It needs a few minutes to equalize the temp and all the condition .

2、  Change a ORP sensor if you want to measure ORP in a solution ,THEN press the MODE key when you’ve changed your sensor。

3、  For Temp compensation , you can easily turn the TEMP knob to the temp in witch the solution is。

 

三、           PH Calibration

1、Put the clean PH sensor into buffer 7.00,a few agitation,wait for the reading to stabilize(suggest at least 5mins),turn CALIB knob to make the value reach 7.00 steadily。Recommend tuning slowly.

2、Wash the sensor with distilled water and wipe it with soft tissue。

3、Put the clean PH sensor into buffer 4.00(or 9 .18), agitate a little,wait for the reading to stabilize(suggest at least 5mins),turn CALIB knob to make the value reach 4.00(or 9.18) steadily。

4、You may repeat the calibration process for 2-3 times for accuracy。

 

NOTE:1、When calibrate ORP sensor please select the right ORP standard。

              2  pH sensor ‘s Temp range is  0-80℃

              3、PH value is a parameter related to Temp, for accurate measure temp compensation is necessary . 

4、storage for a long time ,such as weeks or months ,the sensor should be cleaned sufficiently。